Buffer & Purification Calculator

Blue = auto-calculated
How it works: Define your column dimensions and build a purification protocol step by step. Add steps with column volumes (CV), enter only the flow rate (linear or volumetric) or the residence time. The calculator computes volumes, flow rates, and step times. Use the chemical database to add buffer components — molecular weight auto-fills for instant mass-to-weight conversion. The green/red buttons allows you to add or remove components for each solution/buffer. The component totals table shows the total mass of each component required for the entire protocol and per cycle.
Purification Protocol
Column volume feeds every step
cm
cm
Step CV Volume (mL) Flow (cm/h) Flow (mL/min) Residence Time (min) Step time (min)
Total Volume
Process Time
Formulae
Vcol = π × (ID / 2)2 × H
Volume = CV × Vcol  ·  Residence = (H / Flow) × 60
Step time = Residence × CV  ·  Process time = Σ Step time / 60
Solutions Components
Pick a component → MW auto-fills
Step Component Formula MW (g/mol) Concentration Weight (g/L) Amount / cycle Add
Remove
Formulae
Weight (g/L) = Conc (mol/L) × MW (g/mol)
Amount / cycle = Weight (g/L) × Step Volume (L)
Component Totals
Amount of each component summed across every step
Component Formula Total / cycle
Formulae
Totali = Σ Weight / cyclei, step